When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification test to validate the absence of voltage. This process includes a number of stages that can be complex and time-consuming when using hand-held portable test instruments.
The VeriSafe™ Absence of Voltage Tester from Panduit simplifies this process by automating the absence of voltage verification process
Once installed, a simple push of a button enables qualified electrical workers to verify the absence of voltage and see an active indication when the absence of voltage is confirmed. This provides a new and innovative way to safely, reliably, and efficiently verify the absence of voltage before accessing potentially dangerous electrical equipment.
MPN | Description | |
---|---|---|
VS-AVT-C02-L10 | Panduit VeriSafe Absence of Voltage Tester, Battery, 600 VAC/VDC Max Measurable | Product details |
VS-AVT-C08-L10 | Panduit VeriSafe 1/2/3-Phase Absence of Voltage Tester, Battery, 600 VAC/VDC Max Measurable | Product details |
Video: Panduit VeriSafe - Absence of Voltage Tester (AVT)
Video: VeriSafe Absence of Voltage Tester Demonstration
By automating this process, the VeriSafe™ Absence of Voltage Tester
- Reduces the risk of exposure of electrical hazards for improved worker safety
- Reduces testing procedure time and complexity to improve productivity
- Supports compliance when used as part of the lockout/tagout process described in NFPA 70E
The VeriSafe™ Absence of Voltage Tester minimizes risk by verifying the absence of voltage before equipment is accessed, making it easier for qualified electrical workers to determine an electrically safe environment in a fraction of the time compared to hand-held portable test instruments.
Key Features | Benefits |
---|---|
Improved Safety & Risk Reduction | Determine voltage status BEFORE equipment is accessed Prevents direct exposure to electrical hazards |
Increased Productivity | Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions |
Simplified Process for Easier Compliance | Test sequence based on the steps in NFPA 70E for verification of an electrically safe work condition Automated test helps reduce operator errors |
Reliable Results | Fail-safe design with active indications Safety functions meet SIL 3 per IEC 61508-1 |
Flexible Applications | Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage |